Description
● Auto power off.
● Data hold.
● Low Battery Display.
MASTECH MS5908C Circuit Analyzer: Comprehensive Electrical Testing Tool
The MASTECH MS5908C Circuit Analyzer is an essential tool for evaluating electrical systems, offering a broad range of measurements to ensure safety and performance. This compact and lightweight device is ideal for professionals needing accurate and reliable results in various environments.
Key Features:
- Multifunctional Measurement: Line voltage, peak line voltage, impedance, neutral-ground voltage, and more.
- GFCI Test Function: Evaluates GFCI outlets to ensure proper operation and fault detection.
- RCD Test: Facilitates Residual Current Device (RCD) testing, ensuring circuit safety.
- Data Hold: Allows users to freeze displayed readings for easier analysis.
- Backlight: Easy to read in dim environments.
- Safety Certified: CAT III 300V rating for secure operation.
- Additional Features: Auto power off and low battery display.
Specifications:
- Line Voltage: 85.0~265.0V
- Peak Line Voltage: 120.0~375.0V
- Voltage With Loading Equipments: 0~265.0V
- Line Frequency: 45.0~65.0Hz
- Impedance-Live, Neutral & Earth: 0.00~3.00Ω / >3.00Ω
- Neutral-Ground Voltage: 0.0~10.0V
- RCD/GFCI Trip Time: 1ms~6.5S
- RCD Trip Current: 30mA~37mA
- GFCI Trip Current: 6mA~9mA
- Voltage Drop: 0.1~99.9%
- Voltage Drop Load Current: 5/8/10A
Benefits:
- Versatility: Multiple functions to test a wide range of electrical parameters.
- Safety: RCD/GFCI testing ensures systems meet safety standards.
- Ease of Use: Compact design with intuitive features like data hold and auto power off.
- Reliability: CE, ETL, and RoHS certifications for dependable performance.
BRAND: MASTECH
DELIVERY: 7-15 days
WARRANTY: 12 Months
COUNTRY OF ORIGIN: China
Import Duties : Applicable
Specifications
Line Voltage:
• Range: 85.0 ~ 265.0 V
• Resolution: 0.1 V
• Accuracy: ±(1.0% + 2)
Peak Line Voltage:
• Range: 120.0 ~ 375.0 V
• Resolution: 0.1 V
• Accuracy: ±(1.0% + 2)
Voltage with Loading Equipment:
• Range: 10.0 ~ 265.0 V
• Resolution: 0.1 V
• Accuracy: ±(2.5% + 2)
Line Frequency:
• Range: 45.0 ~ 65.0 Hz
• Resolution: 0.1 Hz
• Accuracy: ±(1.0% + 2)
Impedance (Live–Neutral & Earth):
• Range: 0.00 ~ 3.00 Ω
• Resolution: 0.01 Ω
• Accuracy: ±(2.5% + 2)
Impedance (Above 3.00 Ω):
• Resolution: 0.01 Ω
• Accuracy: Not Ensured
Neutral-Ground Voltage:
• Range: 0.0 ~ 10.0 V
• Resolution: 0.1 V
• Accuracy: ±(2.5% + 2)
RCD Trip Time:
• Range: 1 ms ~ 6.5 s
• Resolution: 1 ms
• Accuracy: ±(1.0% + 2)
RCD Trip Current:
• Range: 30 mA ~ 37 mA
• Resolution: 0.1 mA
• Accuracy: ±(1.0% + 2)
GFCI Trip Time:
• Range: 1 ms ~ 6.5 s
• Resolution: 1 ms
• Accuracy: ±(1.0% + 2)
GFCI Trip Current:
• Range: 6 mA ~ 9 mA
• Resolution: 0.1 mA
• Accuracy: ±(1.0% + 2)
Voltage Drop:
• Range: 0.1% ~ 99.9%
• Resolution: 0.10%
• Accuracy: ±(2.5% + 2)
Voltage Drop Load Current:
• Supported Load Currents: 5 A / 8 A / 10 A
Features:
• Measures line and peak voltage up to 375 V
• Tests impedance between live, neutral, and earth connections
• Supports RCD and GFCI trip time and current testing
• Calculates voltage drop percentage under load conditions
• Compatible with 5 A, 8 A, and 10 A load current testing
General Inquiries
There are no inquiries yet.
Reviews
There are no reviews yet.