| Datasheet | MIN 3000TL-XH-US | MIN 3800TL-XH-US | MIN 5000TL-XH-US | MIN 6000TL-XH-US | MIN 7600TL-XH-US | MIN 8200TL-XH-US | MIN 9000TL-XH-US | MIN 10000TL-XH-US | MIN 11400TL-XH-US |
|---|---|---|---|---|---|---|---|---|---|
| Input data (PV) | |||||||||
| Max. recommended PV power (STC) | 6000W | 7600W | 10000W | 12000W | 15200W | 16400W | 18000W | 20000W | 22800W |
| DC/AC ratio | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 2 | ||||||||
| Max. DC system voltage | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 600V | ||||||||
| Startup voltage | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 80V | ||||||||
| Full load voltage range | 120-500V | 150-500V | 200-500V | 160-500V | 200-500V | 160-500V | 180-500V | 200-500V | 220-500V |
| Nominal voltage | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 360V | ||||||||
| Operating voltage range | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Growatt Battery: 50-550V / LG Battery: 50-450V | ||||||||
| No. of MPPT | 2 | 2 | 2 | 3 | 3 | 4 | 4 | 4 | 4 |
| No. of PV strings per MPPT | 2/2 | 2/2 | 2/2 | 2/2/2 | 2/2/2 | 2 | 2 | 2 | 2 |
| Max. input current per MPPT | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 13.5A | ||||||||
| Max. short-circuit current per MPPT | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 16.9A | ||||||||
| Input/Output data (battery DC) | |||||||||
| Battery voltage range | Growatt APX Battery: 380V-550V / Growatt ARO Battery: 360V-550V / LG Battery: 360V-450V | ||||||||
| Nominal DC voltage | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 400V | ||||||||
| I/O DC current | 8.9A | 11.1A | 14.4A | 17.2A | 21.7A | 23.6A | 25.8A | 28.6A | 32.5A* |
| I/O DC power | 3200W | 4000W | 5200W | 6200W | 7800W | 8500W | 9300W | 10300W | 11700W* |
| Battery technology | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â LFP | ||||||||
| Battery capacity per module | APX 5kWh / ARO 3.3kWh / LG 10kWh, 16kWh / LG enblock S10: 10.6kWh / LG enblock S14: 14.1kWh / LG enblock S17: 17.7kWh | ||||||||
| Scalability | APX 5.0-30.0kWh / ARO 6.6-39.6kWh / LG Prime 10H 10-20kWh, 16H 16-32kWh / LG enblock S10: 10.6-21.2kWh / S14: 14.1-28.2kWh / S17: 17.7-35.4kWh | ||||||||
| Compatible batteries | Growatt APX HV Battery / Growatt ARO HV Battery / LG 10H Prime / LG 16H Prime / LG enblock S10 / LG enblock S14 / LG enblock S17 | ||||||||
| Output data (AC on-grid) | |||||||||
| AC nominal power@240V AC | 3000W | 3800W | 5000W | 6000W | 7600W | 8200W | 9000W | 10000W | 11400W |
| AC nominal power@208V AC | 2600W | 3290W | 4330W | 5200W | 6580W | 7100VA | 7800VA | 8660VA | 9880VA |
| Max. AC apparent power | 3000VA | 3800VA | 5000VA | 6000VA | 7600VA | 8200VA | 9000VA | 10000VA | 11400VA |
| Nominal AC voltage | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 208V/240V | ||||||||
| AC voltage range @208V AC @240V AC | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 183V-229V / 211V-264V | ||||||||
| AC grid frequency | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 50/60Hz | ||||||||
| AC grid frequency range | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 45-65Hz | ||||||||
| Max. output current | 12.5A | 16A | 21A | 25A | 32A | 35A | 38A | 42A | 48A |
| Max. output overcurrent protection | 20A | 20A | 30A | 40A | 40A | 63A | 63A | 63A | 63A |
| Power factor (@ nominal power) | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â >0.99 | ||||||||
| Adjustable power factor | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 0.8 Leading-0.8 Lagging | ||||||||
| THDi | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â <3% | ||||||||
| AC grid connection type | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â L1/L2/N/PE | ||||||||
| Output data (backup off-grid) | |||||||||
| AC nominal power | 3000W | 3800W | 5000W | 6000W | 7600W | 8200W | 9000W | 10000W | 11400W* |
| Max. AC power output | 4700VA | 6000VA | 7900VA | 9400VA | 12200VA | 12900VA | 14200VA | 15800VA | 18000VA |
| Nominal AC output voltage | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 240V | ||||||||
| Max. output current | 20A | 25A | 33A | 40A | 50A | 54A | 59A | 66A | 75A |
| THD | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 2% linear load, 5% non-linear load | ||||||||
| AC Port-V2 inverter | 2 AC Ports, 1 for ON Grid, 1 for Backup (EPS) compatible with ATS-US for Partial Home Backup | ||||||||
| AC Port-V3 inverter | 1 AC Port for 1 ON Grid compatible with SYN200-US for Whole Home Backup | ||||||||
| Efficiency | |||||||||
| Max. efficiency | 97.0% | 98.0% | 98.2% | 98.4% | 98.4% | 98.3% | 98.3% | 98.3% | 98.5% |
| CEC efficiency@240V AC | 97.0% | 97.0% | 97.5% | 97.0% | 97.5% | 97.5% | 97.5% | 97.5% | 98.0% |
| CEC efficiency@208V AC | 96.5% | 97.0% | 97.5% | 97.0% | 97.0% | 97.5% | 97.5% | 97.5% | 97.5% |
| Protection devices | |||||||||
| DC reverse-polarity protection | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| DC switch | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| DC surge protection | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Type II | ||||||||
| Insulation resistance monitoring | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| AC surge protection | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Type III | ||||||||
| AC short-circuits protection | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| Ground fault monitoring | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| Grid monitoring | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| Anti-islanding protection | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| Residual-current monitoring unit | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| AFCI protection | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| General data | |||||||||
| RSD Transmitter | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Tigo/APs/FUDA | ||||||||
| Dimensions (W/H/D) | 15.75/22.41/6.98 inch (400/569/170.5mm) | 15.8/25.2/7.4 inch (400/638/187mm) | |||||||
| Weight | 32.3lbs (14.65kg) | 45.2lbs (20.5kg) | |||||||
| Operating temperature range |                     -13°F~+140°F (-25°C~+60°C), de-rating above 113°F | ||||||||
| Altitude | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 9843ft (3000m) | ||||||||
| Internal consumption at night | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â <1W (for PV inverter) / <5W (for storage inverter) | ||||||||
| Cooling | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Natural Convection | ||||||||
| Electronics protection degree | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â NEMA4X (IP65) | ||||||||
| Relative humidity | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â 0-95% | ||||||||
| Interfaces | |||||||||
| RS485 | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes | ||||||||
| WiFi/4G communication | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Optional | ||||||||
| RSD compliance | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â UL1741 PVRSS/NEC2020 690.12 | ||||||||
| Warranty: 10 Years | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Yes (optional for extended 15 and 20 years warranty) | ||||||||
| Revenue grade meter | Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â ANSI C12.20 (meet 0.5% accuracy) | ||||||||
BRAND: Growatt
DELIVERY: 7-15 days
WARRANTY: 12 Months
COUNTRY OF ORIGIN: China
Import Duties : Applicable
General Inquiries
There are no inquiries yet.
Fast Shipping
Eco Friendly
Genuine Products
Customer Care

Solar Generator
Frequent Asked Questions
We offer free shipping on all orders, regardless of the order value or delivery.
Yes, all transactions on mobilecasez.com are encrypted and securely processed through trusted gateways. We do not store any payment details on our servers.
You have 7 days from the date you receive your order to initiate a return, no exchange
Standard international shipment may take approximately 20 (twenty) Business Days unless otherwise specifically mentioned in the product details. Priority international shipment may take approximately 8 (eight) Business Days unless otherwise specifically mentioned in the product details.
Yes, we currently ship all over the world.
Replacement can be made if the Customer establishes that the product was delivered in defective condition or has physical damage within 24 (twenty-four) hours of receipt of the product.
We will organize to repair the damaged product, collect it, and replace it with an equivalent product, or provide a refund, provided that you contact us within 24 (twenty-four) hours of receipt of the product.
Any damaged product must be returned in the condition it was in when you received it, together with any packaging and other items that you received with the damaged product.